LACO Technology's Titan Test Helium Leak Detection Systems provide the lowest cost automated helium leak detection system on the market. Designed for small parts, the Titan Test System can be used to leak test parts in applications like medical, electronics and valves. The Titan Test can be set up for one button start along with data logging capability. Various sized chambers can be added to the system along with automated opening lids for the best in low cost leak detection systems.

FLEXSTATION™ Leak Test Systems provide leak testing system solutions for low to mid level volumes. Custom chambers can be mixed and matched with the system to provide a cost effective chamber leak test systems for multiple parts. Test gases include, helium, hydrogen and other alternative test gases. The FLEXSTATION™ offers configurable hardware and software options. In addition, due to its modular construction, it can grow as your leak checking needs increase.

LACO Technologies,  provides complete custom leak test solutions uniquely built for your application. Leak testing methods include using tracer gases such as helium, hydrogen (5% non-combustible), pressure decay(air), mass flow, and other tracer gas techniques. Part sizes can range from tiny to quite large, so there are no size restrictions. Applications include automotive components, refrigeration equipment, medical devices, electrical devices and packages, appliances and components, and industrial fluid handling components.


Titan Test Options

Air Leak Tester

Air leak detection system

Helium Charge System

Helium Charge System for helium leak detection

Helium Bombing System

helium leak detection bombing chamber

Air leak detection can be in the form of pressure decay, bubble immersion or mass flow. Each system measures the air in or air out of an enclosed system under pressure or vacuum. The Aura is an automated multi-functional air leak tester designed for demanding air leak check applications. Two versions are available, the compact so single part testing and multi-test providing multiple part testing and full data logging.

Helium leak detection of an enclosure of object requires filling of helium to a specified pressure. Automation of the helium charging process includes evacuation, proof testing, and decay testing in conjunction with the actual helium leak test. The Helium Charging Station can be used with the Titan Test to automate the test procedure.

Production leak detection of small electronic parts requires the injection of helium into the part enclosure to test the seal integrity. Helium bombing systems allow these parts to be "bombed" with helium molecules to allow the seal integrity leak check. A number of sizes are available to handle the variety of part sizes.

Leak Detection Vacuum Chambers

Vacuum Chambers for Helium Leak Detection

Calibrated Leak Standards

Calibrated Leak

Helium Spray Probes & Sniffer Probes

Leak Detection Sniffer Probe
Leak Detection Sniffer Probe

Our vacuum leak detection chambers fit to the Titan Test Leak Detection Systems to provide the vacuum chamber enclosure for leak testing small parts. Leak test chambers can have a manual or automated lid to allow automation of the helium leak test.

Calibrated leak standards are intended to insure your leak detection system is within calibration. The accepted manner is to compare a known calibrated standard using a calibrated leak. Calibrated leaks can contain, air, helium, hydrogen or other tracer gas.

Helium Spray Guns dispense the proper amount of helium for an outside-in helium leak test. Sniffer probes pull tracer gas in inside-out pressurized systems to detect helium or other tracer gas like hydrogen (5%).


Type of Leak Detection System Applicable by Application

Automotive * Aerospace * Electronics * Medical * Industrial * Packaging * Power Generation * Refrigeration

Checkmarks represent most common leak detection platform

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Automotive

Fuel tank leak detection

Automotive fuel tanks, pumps, hoses, and other automotive components require leak testing to insure both liquid and vapors do not escape from the fuel system.

Air Bag Actuator

Safety components such as airbags are inflated by gas produced during the release of stored gas. 

Hydraulic Systems

Hydraulic components and systems in automotive and transportation applications require leak testing to prevent leakage of hydraulic fluid.

Engine & Exhaust Components

Automotive engine and exhaust components require leak testing to insure seals contain fluids and gases.

 

A/C Components

A/C components and complete A/C systems in automotive applications require leak testing to prevent loss of refrigerant that will affect the life and performance of the system as well as potentially harm the environment.

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Aerospace

Aircraft Engine Control Modules

This manufacturer needed an efficient method for leak testing their aircraft engine control modules

Ventilation Systems

Aircraft ventilation and A/C systems and components require leak testing to insure proper operation.

Instrumentation System & Navigation Systems

Instruments and navigation systems are often leak tested to very stringent leak rates. These include altimeters, gyroscopes, electronic enclosures and other components.

Engine & Exhaust Components

Automotive engine and exhaust components require leak testing to insure seals contain fluids and gases.

 

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Electronics

Electrical Enclosures

Electrical enclosures are used in outdoor, underwater or other extreme environments that require leak testing to insure seal integrity.

Electronic Components

Electronic components require seal integrity to prevent water intrusion into the package, shortening lifetime.

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Medical

Disposable Medical 

Disposable devices such as catheters, syringes must be leak checked to insure non-contaminated operation in medical devices.

Sterile Connectors

Molding and assembly of a new plastic part called sterile connectors are used in bioprocessing. Easier processing and lack of contamination is required to insure a sterile product.

Medical Implants

Seal integrity in pacemakers, artificial hearts, and other devices are critical to insure a long lasting patient solution.

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Packaging

PHARMACEUTICAL PACKAGING

Blister packs, bio process containers, liquid-filled syringes and liquid filled & lyophilized vials require protection from bacteria, air contamination and moisture.

Food and Beverage Packaging

Preserving shelf life and quality of sterility of perishable products that can be affected my moisture and oxygen.

Chemical and Gas Storage

Liquid and gas containers in applications such as liquid natural gas (LNG containers) along with other chemicals and gases must be leak checked to protect the environment and/or public safety.

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Industrial 

Fire Extinguishers

Fire extinguishers and components must be helium leak checked to prevent pressure loss during a normal product lifetime and to insure proper operation in an emergency situation.

Pressure Valves & Vacuum Valves

Valve manufacturing requires leak detection to insure valve seat, stem seal, and valve body leak tightness.

Gas Regulators

Gas regulators and components, including valves, tanks and regulators must be  leak tight to function properly and prevent gas loss. 

Cryogenic Cylinders

Cryogenic cylinders must be leak tested so that product remains in the container. Cryogenic cylinders keep oxygen, nitrogen, carbon dioxide and other gases under pressure at room temperatures to maintain their liquefied state.

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Power Generation

Batteries

Liquid and Dry type batteries of all types require leak tight enclosures to meet lifetime expectations.

Switchgear

Gas Insulated high voltage switchgear require leak tightness to prevent  SF6 loss. 

Transformers

Leaks defects can cause failure and impact safety and performance of power transformers.

Cryogenic Cylinders

Cryogenic cylinders must be leak tested so that product remains in the container. Cryogenic cylinders keep oxygen, nitrogen, carbon dioxide and other gases under pressure at room temperatures to maintain their liquefied state.

Application

Titan Test

FLEXSTATION

Custom System

Air Leak System

Refrigeration

Refrigeration Compressor

Refrigeration compressors need leak testing to insure leak tightness of static and dynamic seals.

Refrigerant Coils

Refrigerant coils including condensers and heat exchangers require tight weakness specifications to prevent refrigerant loss causing premature product failure.

Control Valves

Refrigeration control valves are leak tested to check valve seat leaks to insure no refrigerant loss.

 

Cryogenic Cylinders

Cryogenic cylinders must be leak tested so that product remains in the container. Cryogenic cylinders keep oxygen, nitrogen, carbon dioxide and other gases under pressure at room temperatures to maintain their liquefied state.